Soluble Fiber Blanket

Soluble Fiber Textiles

Soluble Fiber Blanket

Code prefix AB

Soluble ceramic fiber blanket, also called low-biopersistence fiber blanket, is needled from soluble fiber and produced in a range of thicknesses and densities. The fiber is of the calcium-magnesium type and combines high-temperature resistance with low biopersistence. The blanket has tensile strength and a low shot content, so it can be cut, fabricated and installed in the usual ways. It meets the 97/69 EC NOTA Q exemption and is not classified as a carcinogen.

Continuous
1000°C
1832 °F
Short peak
1300°C
2372 °F
Construction
Unreinforced
AB

Spec sheets are issued against the confirmed grade, with the test method named on the report.

01 — Product description

Product description

Soluble ceramic fiber blanket, also called low-biopersistence fiber blanket, is needled from soluble fiber and can be produced in a range of thicknesses and densities. The fiber is of the calcium-magnesium type and combines high-temperature resistance with low biopersistence. The blanket has tensile strength and a low shot content, so it can be cut, fabricated and installed in the usual ways.

Product characteristics

  • Thermal insulation performance.
  • Thermal stability.
  • Low heat storage.
  • Tear resistance.
  • Thermal shock resistance.
  • Complies with the 97/69 EC NOTA Q standard and is not classified as a carcinogen.

Product data

PropertyGrade 1Grade 2
Classification temperature1200 C1300 C
Density (kg/m³)96 / 12896 / 128
Classification temperature and density
Mean temperatureConductivity range
200 C0.05 – 0.08
400 C0.08 – 0.13
600 C0.12 – 0.16
800 C0.15 – 0.18
1000 C0.25 (1300 C grade)
Thermal conductivity (W/m·K, mean temperature)
Thickness (mm)Length (mm)Width (mm)
1314640610
257320610
384880610
503660610
Standard dimensions

Note: the classification temperature is the product's classification rating and does not equal continuous service temperature. Actual service temperature depends on the duty, load and atmosphere.

Working limits

The blanket is intended for dry static insulation duty. It is not suitable for strong acid or alkali corrosion, long-term liquid immersion, high-velocity media erosion or high-frequency heavy rubbing.

Precautions

  • Cutting and installation generate fiber dust; keep the area ventilated, wear dust protection, and dispose of waste under local environmental regulations.
  • The classification temperature is a product rating only and must not be treated as the long-term service temperature; select the grade against the actual duty.
  • Inspect at intervals during service and replace the blanket when it powders, cracks or is damaged.
  • All technical data are for reference; actual performance depends on the conditions of use, so carry out a suitability test and follow the relevant safety regulations and standards.

02 — Characteristics

Two classification grades

1200 C and 1300 C grades, each available at 96 and 128 kg/m³.

Low shot content

Needled blanket with tensile strength for cutting, fabrication and installation.

Thermal shock resistance

Insulation performance, thermal stability, low heat storage and resistance to tearing.

Low biopersistence

Calcium-magnesium AES fiber meeting the 97/69 EC NOTA Q exemption.

03 — Typical properties

Values typical, confirm against duty

Test itemValueNote
Fiber97/69 EC NOTA Q
ClassificationNot a continuous rating
DensityBoth grades
ThicknessStandard
WidthStandard
LengthBy thickness

04 — Standard sizes

Product codeDimensions
AB1313 mm × 610 mm × 14640 mm
AB2525 mm × 610 mm × 7320 mm
AB3838 mm × 610 mm × 4880 mm
AB5050 mm × 610 mm × 3660 mm

05 — Where it is used

  • Dry static insulation for kilns and high-temperature equipment
  • Backup insulation behind dense refractories
  • High-temperature pipe and vessel insulation
  • Expansion joint and gap insulation
  • Thermal barriers in industrial and transport equipment

Service limits

  • The classification temperature is a product classification figure and does not equal continuous service temperature; select against the actual duty, load and atmosphere.
  • Dry static insulation duty only: not for strong acid or alkali, long-term liquid immersion, high-velocity media erosion or frequent heavy rubbing.
  • Cutting and installation release fiber dust; ventilate the work area, wear dust protection and dispose of waste under local environmental regulations.
  • Inspect at intervals and replace the blanket when it powders, cracks or is damaged.