Ladder Fiber Tape

Ceramic Fiber Textiles

Ladder Fiber Tape

Code prefix TL

The ladder fiber tape family covers glass fiber, ceramic fiber and bio-soluble fiber versions, and the base material decides the basic performance of each. The ladder structure leaves openings along the tape so bolts can pass through, which is why it is fitted across flange and bolted joints to provide thermal insulation and auxiliary sealing. It is a low-pressure static material and is not a high-pressure gasket.

Continuous
1000°C
1832 °F
Short peak
1000°C
1832 °F
Construction
Unreinforced
TL

Spec sheets are issued against the confirmed grade, with the test method named on the report.

01 — Product description

High-Temperature Resistant Fiber Ladder Tape

Product description

High-temperature resistant fiber ladder tape includes fiberglass ladder tape, ceramic fiber ladder tape, biosoluble fiber ladder tape, and other series. The basic performance of the product is determined by the base material.

The ladder tape structure facilitates bolt passage and is suitable for flange and bolted connection locations, providing thermal insulation and auxiliary sealing functions. It is only suitable for low-pressure static conditions and cannot be used as a high-pressure sealing component.

Product specifications

Product CodeMaterialThickness (mm)Width (mm)Working Temperature (°C)
GTLX-YYFiberglassXYY550°C (reference short-term tolerance temperature under static no-load conditions)
CTLX-YYCeramic fiberXYY1000°C (specific analysis required for specific conditions)
BTLX-YYBiosoluble fiberXYY1000°C (specific analysis required for specific conditions)

Note: X and YY in the table are variable specification parameters; thickness and width dimensions can be customized as needed.

Application scope

Applicable scenarios:

- Thermal insulation for industrial kilns, high-temperature pipelines, and high-temperature vessels;

- Low-pressure static thermal insulation auxiliary sealing for furnace doors, valves, and flange locations;

- High-temperature thermal insulation protection for engines and instrument equipment;

- Flue lining thermal insulation gaskets.

Packaging

30 m/roll or 50 m/roll, single-roll independent plastic bag packaging.

Usage precautions

  • Cutting and grinding of ceramic fiber ladder tape generate fiber dust. During operation, wear dust masks and protective gloves, and ensure ventilation protection; biosoluble fiber products are also recommended to have dust protection. Dispose of waste in accordance with local environmental regulations.
  • Product temperatures are reference working condition values. Continuous use temperatures and short-term tolerance temperatures differ among different materials. Use beyond the design temperature is strictly prohibited.
  • The product can only achieve low-pressure static auxiliary sealing. Under high-pressure or high-vibration conditions, sealing failure and material damage may occur.
  • During use, conduct regular inspections. In case of powdering, cracking, or damage, replace promptly.
  • All technical data are for reference only. Actual performance depends on usage conditions. Users should conduct their own suitability testing and comply with relevant safety regulations and standards.

02 — Characteristics

Ladder structure

Open gaps along the tape let bolts pass through, so the tape sits across a bolted joint without being drilled or cut away.

Three base materials

Glass fiber, ceramic fiber and bio-soluble fiber; the base material sets the temperature class and the mechanical behaviour.

Flange and bolted joints

Insulation and auxiliary sealing at flanges, valves and furnace doors working at low pressure and static conditions.

Thickness and width to order

Thickness X and width YY are variable parameters; both are made to the joint rather than supplied from a fixed list.

03 — Typical properties

Values typical, confirm against duty

Test itemValueNote
ConstructionOpen structure for bolt access
Base materialSets the temperature class
Reference, glassStatic, no load, short-time
Reference, ceramicAssessed case by case
Reference, solubleAssessed case by case
ThicknessVariable, to order
WidthVariable, to order
PackagingIndividual plastic bag

04 — Standard sizes

Product codeDimensions
GTLX-YYGlass fiber, thickness X, width YY
CTLX-YYCeramic fiber, thickness X, width YY
BTLX-YYBio-soluble fiber, thickness X, width YY

05 — Where it is used

  • Low-pressure static sealing at furnace doors, valves and flanges
  • High-temperature protection for engines and instruments
  • Flue liner insulation gaskets

Service limits

  • Low-pressure static auxiliary sealing only: not for high pressure, liquid media, strong corrosives, high-velocity gas, heavy vibration or repeated rubbing.
  • Not a high-temperature filter medium, and not recommended as direct fire-rated cable wrap.
  • Cutting and grinding release fiber dust; use a dust mask and gloves with adequate ventilation.
  • Temperature values are reference figures; never exceed the design temperature, and replace the tape when powdering, cracking or damage appears.

Ladder Fiber Tape

TL

Request a quote