Mica Packing

Flexible Fabricated Products

Mica Packing

Code prefix MPK

Mica packing uses phlogopite as the main raw material, braided with various high-temperature resistant materials to form a sealing packing. It suits temperature fluctuation conditions, with a short-term tolerance temperature of 1000 C and a conventional use range of -200 C to 850 C. The packing provides thermal insulation, thermal stability, low thermal conductivity, low heat storage and sound absorption.

Continuous
850°C
1562 °F
Short peak
1000°C
1832 °F
Construction
Unreinforced
MPK

Spec sheets are issued against the confirmed grade, with the test method named on the report.

01 — Product description

Phlogopite for temperature cycling

Mica packing uses phlogopite as the main raw material, braided with various high-temperature resistant materials to form a sealing packing. It is suitable for temperature fluctuation conditions, with a short-term tolerance temperature of 1000 C and a conventional use range of -200 C to 850 C. The packing provides thermal insulation, thermal stability, low thermal conductivity, low heat storage and sound absorption.

Test itemParameter
Tensile strength≥ 820 MPa
Elongation≥ 30 %
Short-term tolerance temperature1000 C
Minimum use temperature-200 C
Product parameters

Scope of application

Suitable for high-temperature valve stem sealing and annular sealing under temperature fluctuation conditions, with a conventional applicable range of -200 C to 850 C.

Working condition suitability and restrictions

850 C is the conventional continuous temperature and 1000 C only the short-term tolerance; long-term over-temperature operation is not allowed. The packing suits dry, high-low temperature alternating static and low-speed sealing. It is not suitable for high-speed medium erosion, high-frequency severe friction, strong impact loads or long-term immersion, which cause wear, structural failure and sealing leakage.

Usage precautions

  • Match working temperature, pressure and medium parameters before installation; long-term use beyond the limits is prohibited.
  • Suitable for media with a large acid-base span; extremely corrosive conditions need prior suitability testing.
  • Inspect the seal regularly and replace on wear, hardening, cracking or leakage.
  • All technical data are for reference; users should test suitability and follow relevant safety regulations.

02 — Characteristics

Temperature fluctuation

Developed for alternating high and low temperature duty, with a 1000 C short-term tolerance.

Wide working range

Conventional use from -200 C to 850 C.

Mechanical values

Tensile strength ≥ 820 MPa and elongation ≥ 30 % in the declared test.

Insulation and damping

Low conductivity, low heat storage and sound absorption in one braided section.

03 — Typical properties

Values typical, confirm against duty

Test itemValueNote
Raw materialBraided packing
Tensile strengthTest value
ElongationTest value
Continuous rangeConventional
Short-termNot a continuous rating

04 — Standard sizes

Product codeDimensions
MPK-SQSquare section, to gland size
MPK-RDRound section, to gland size
MPK-CUSTOMSection and length to order

05 — Where it is used

  • High-temperature valve stem sealing
  • Annular sealing under temperature fluctuation
  • Static and low-speed sealing duty
  • Equipment with alternating temperatures

Service limits

  • 850 C is the conventional continuous temperature and 1000 C only the short-term tolerance; long-term over-temperature operation is not allowed.
  • For dry, high-low temperature alternating static and low-speed sealing: not for high-speed media erosion, high-frequency severe friction, strong impact loads or long-term immersion.
  • Match temperature, pressure and medium parameters before installation; strongly corrosive media need prior suitability testing.
  • Inspect the seal at intervals and replace on wear, hardening, cracking or leakage.